HCCP system at wellsite are composed of several parts: heating composite continuous pipeline, end fittings, control cabinet, pressure and temperature monitoring device. The crude oil product by each well were gathered firstly, then heated to the specified temperature by HCCP system.
● Rated power 15 kW
(1) Main parameters of HCCP system
Length | 30 m |
Inside Diameter | 50 mm |
Pressure rating | 6.4 MPa |
outside diameter | 76 mm(glass fiber reinforced) |
78 mm(aramid fiber reinforced) | |
Heating power | 15 kW |
Working voltage | 380 V |
(2) Exposition of heating efficiency
10 m³/d crude oil with water content of more than 50% can reach temperature rise of 30 ℃ .
● Rated power 30 kW
(1) Main parameters of HCCP system
Length | 60 m |
Inside Diameter | 50 mm |
Pressure rating | 6.4 MPa |
outside diameter | 76 mm(glass fiber reinforced) |
78 mm(aramid fiber reinforced) | |
Heating power | 30 kW |
Working voltage | 380 V |
(2) Exposition of heating efficiency
25 m³/d crude oil with water content of more than 50% can reach temperature rise of 30 ℃ .
● Rated power 45 kW
(1) Main parameters of HCCP system
Length | 100 m |
Inside Diameter | 50 mm |
Pressure rating | 6.4 MPa |
outside diameter | 76 mm(glass fiber reinforced) |
78 mm(aramid fiber reinforced) | |
Heating power | 45 kW |
Working voltage | 380 V |
(2) Exposition of heating efficiency
35 m³/d crude oil with water content of more than 50% can reach temperature rise of 30 ℃ .