HCCP System at Wellsite

Details

HCCP system at wellsite are composed of several parts: heating composite continuous pipeline, end fittings, control cabinet, pressure and temperature monitoring device. The crude oil product by each well were gathered firstly, then heated to the specified temperature by HCCP system. 

● Rated power 15 kW

(1) Main parameters of HCCP system


Length

30 m

Inside Diameter

50 mm

Pressure rating

6.4 MPa

outside diameter 

76 mm(glass fiber reinforced)

78 mm(aramid fiber reinforced)

Heating power

15 kW

Working voltage

380 V


(2) Exposition of heating efficiency

10 m³/d crude oil with water content of more than 50% can reach temperature rise of 30 ℃ .

● Rated power 30 kW

(1) Main parameters of HCCP system

Length

60 m

Inside Diameter

50 mm

Pressure rating

6.4 MPa

outside diameter

76 mm(glass fiber reinforced)

78 mm(aramid fiber reinforced)

Heating power

30 kW

Working voltage

380 V


(2) Exposition of heating efficiency

25 m³/d crude oil with water content of more than 50% can reach temperature rise of 30 ℃ .

● Rated power 45 kW

(1) Main parameters of HCCP system

Length

100 m

Inside Diameter

50 mm

Pressure rating

6.4 MPa

outside diameter

76 mm(glass fiber reinforced)

78 mm(aramid fiber reinforced)

Heating power

45 kW

Working voltage

380 V

(2) Exposition of heating efficiency

35 m³/d crude oil with water content of more than 50% can reach temperature rise of 30 ℃ .